Temperature Range
|
0 °C to +300°C
|
Heating Rates
|
0.1°C /minute to 120°C / minute
|
Cooling Rates
|
0.1°C/minute to 100°C/minute
|
Chamber Variation
|
+/- 5°C
|
Dimensions*
|
990 mm wide x 520 mm high x 610 mm deep
|
Maximum board size
|
300 mm x 250 mm
|
Maximum component height
|
30 mm (with standard board holder)
|
Power Consumption
|
12 kWmax (3 phase supply)
|
Cooling
|
Liquid Nitrogen at 22 psi
|
Controls
|
Simple two key RUN/STOP operation
|
Display
|
3.5 digit LCD for monitoring chamber and one additional probe
|
Communications
|
RS232 port for interfacing withT-Time Windows based Thermal Management Software
|
Storage Temperature
|
-10°C to +50°C
|
Storage Humidity
|
5% to 95% RH non-condensing
|
Operating Ambient Temperature
|
-10°C to +50°C
|
Operating Ambient Humidity
|
5% to 95% RH non-condensing
|
Fume Extraction Option
|
Extraction ports for attachment of external filter - HEPA (High Efficiency Particulate Arrestance) composite filter removes 99.97% of particles down to 0.3 microns
|
*(Excluding ducts, isolator and handles)
|