Temperature Range

0 °C to +300°C

Heating Rates

0.1°C /minute to 120°C / minute

Cooling Rates

0.1°C/minute to 100°C/minute

Chamber Variation

+/- 5°C

Dimensions* 

990 mm wide x 520 mm high x 610 mm deep

Maximum board size

300 mm x 250 mm

Maximum component height

30 mm (with standard board holder)

Power Consumption

12 kWmax (3 phase supply)

Cooling

Liquid Nitrogen at 22 psi

Controls

Simple two key RUN/STOP operation

Display

3.5 digit LCD for monitoring chamber and one additional probe

Communications

RS232 port for interfacing withT-Time™ Windows™ based Thermal Management Software

Storage Temperature

-10°C to +50°C

Storage Humidity

5% to 95% RH non-condensing

Operating Ambient Temperature

-10°C to +50°C

Operating Ambient Humidity

5% to 95% RH non-condensing

Fume Extraction Option

Extraction ports for attachment of external filter - HEPA (High Efficiency Particulate Arrestance) composite filter removes 99.97% of particles down to 0.3 microns

*(Excluding ducts, isolator and handles)